113
‐
Maintenance Schedule
Regular Service Period (5)
Item
Each
use
Every 6
months
or 50
hrs.
Every
1 year
or 100
hrs.
Every 2
years
or 300
hrs.
Engine oil
Check level
⊙
Change
⊙
(1)
Air cleaner
Clean
⊙
(2)
Spark plug
Check-adjust
⊙
Replace
⊙
Spark arrester
Clean
⊙
Valve Clearance Check-adjust
⊙
(3)
Combustion
Chamber
Clean
⊙
(3)
Fuel tank & filter
Clean
⊙
Fuel line
Check/Replace
⊙
(3)(4)
NOTE
(1). Change the engine oil after the first 10 hrs.
(2). Service more frequently when used in dusty areas.
(3). These items should be serviced by your servicing dealer, or by
the expertise of professional service personnel.
(4). Replace the fuel line if necessary every 2 years.
(5). The battery of the generator equipped with an electric starter
should be charged no more than 3 months by the matched
charger, or by running the generator more than 5 hrs.
(6). For commercial use, ensure long hours of operation to
determine proper maintenance intervals. Failure to follow this
maintenance schedule could result in non-warrantable failures.