8.
AC PARALLEL OPERATION
Two S
HP
2000i(E) generators that have the same rated voltage
and frequency can be operated in parallel to increase the
total available output power reaching 3.6 kVA. A Parallel Kit
2(optional equipment) is required for the parallel operation.
8.1 STARTING AC PARALLEL
(1). Disconnect or turn off all electrical loads from both generators.
(2). Connect the Parallel Kit 2 between the Parallel Terminals 1 on two
generators.
(3). Start the two engines and make sure the READY LED (green) lights up.
(4). Plug the appliance in receptacles of the Parallel Kit 2.
(5). Turn on the appliance to use.