User Manual
"Steam sterilizer Laboklav 55 - 195
"
Laboklav 160
Overall dimension (free standing unit) (W x H x D)….
840 x 1065 x 700 mm
Footprint (Bench top unit) (W x D)...............................
840 x 975 mm
Weight (netto)..............................................................
ca. 220 kg
Volume Feed Water tank.............................................
ca. 40 l
Maximum Load:
-
Instruments .....................
40 kg
-
Textiles ...........................
25 kg
-
Liquids...........……………..
45 Liter Total volume
Sterilizer chamber:
Total volume ................................................................
ca. 165 l
Chamber dimension (
φ
x D)..........................................
φ
500 x 760 (+50-round.) mm
Usable Volume....... ..................................................…
ca. 163 l
Maximum allowable pressure (PS)...............................
2.8 bar
Maximum allowable temperature (TS)..........................
138°C
Working pressure safety valve.......................................
2.8 bar
Material of chamber and double jacket..................…....
1.4404 (SS 316 L)
Surface roughness ……………………........................…
≤
0,8 µm
Pressure Device Directive 2014/68/EU.........................
CE0036, Kat. II, Modul B+C2
Power supply:
Voltage .........................................................................
3N 400V~ (
±
5%), 50 Hz, 16A
Power cord……..……….................................................
CEE-plug 16 A
Working power ...............................................................
10 kW
Averaged power consumption per cycle.........................
17 kWh
Protection class ......................…………………………...
I
Protection…......................…………………...…………...
IP24
Electromagnetic compatibility ..........……..………………
DIN EN 61326
Water supply:
Destilled or demineralized Water
(acc. to annex C EN 13060)
Averaged feed water consumption per cycle...................
ca. 5,5 l - 17 l
(depending on initial state, program and load)
Storing conditions:
Temperature...................................................................
5
÷
40°C
Humidity ........................................................................
max. 85%
Heat emission to the environment.................................
ca. 12% of rated capacity
Programs:
10 predefined programs in user level 1:
The program definition depends on the available options included in the model. The programs
can be individually changed.
10 further programs in user level 2 (program P11 - P20) code protected, Predefinition is like P1.
2 test programs (Bowie & Dick-Test, P11, vacuum test, P12) - in vacuum versions only
Computer interface:
- serial interface RS 485
Printer (optional)