374
Manual – IPOSplus®
24
"Table positioning" sample program
Assembler – Examples
24.4.3 Input terminals
24.4.4 Output terminals
Level
Terminal
terminal function
Meaning
0
DI00
/Controller inhibit
Switch power section on/off
0
DI01
Enable
Controlled standstill
0
DI02
Reset
Reset after fault (moving clear of limit switches)
0
DI03
Reference cam
Switch for zero or offset value
0
DI04
Limit switch right
Limit switch for stopping (+)
0
DI05
Limit switch left
Limit switch for stopping (-)
0
DI10
IPOS input
Variable pointer bit 2'0
0
DI11
IPOS input
Variable pointer bit 2'1
0
DI12
IPOS input
Variable pointer bit 2'2
0
DI13
IPOS input
Variable pointer bit 2'3
0
DI14
IPOS input
Jog positive
0
DI15
IPOS input
Jog negative
0
DI16
IPOS input
Start reference travel
0
DI17
IPOS input
Start positioning
Level
Terminal
Unit
terminal function
Meaning
0
DB00
MDX
/Brake
Brake control via auxiliary relay
0
DO01
MDX
Ready
Controller active, power supply to electronics OK
0
DO02
MDX
/Fault
no fault
0
DO10
DIO11B
IPOS output
Variable pointer bit 2'0
0
DO11
DIO11B
IPOS output
Variable pointer bit 2'1
0
DO12
DIO11B
IPOS output
Variable pointer bit 2'2
0
DO13
DIO11B
IPOS output
Variable pointer bit 2'3
0
DO14
DIO11B
IPOS output
-
0
DO15
DIO11B
IPOS output
Table position valid
0
DO16
DIO11B
IPOS in position
Drive in positioning window
0
DO17
DIO11B
IPOS reference
Reference travel successfully completed
P
i
f
kVA
Hz
n
P
i
f
kVA
Hz
n