Setting the user travel units
Assembler – Introduction
20
Assembler – Introduction
20.1 Setting the user travel units
In the program header of the Assembler, the travel distance factors "NUMERATOR",
"DENOMINATOR" and "UNIT" can be entered to determine the user travel unit (e.g.
mm, rev.).
20.1.1 Travel distance factors NUMERATOR/DENOMINATOR
IPOS
plus®
always operates with 4096 increments/motor revolution The user may wish
to program travel commands in user units other than increments/motor revolution (e.g.
mm, revs.). In this case, the "NUMERATOR" and "DENOMINATOR" travel distance fac-
tors must be set as described below. Exceptions to this are travel commands with vari-
ables as their argument. These can only be specified in increments/motor revolution.
The conversion is carried out as follows:
Increments =
NUMERA-
TOR
· User travel unit