SENKO pellet SLIM MODERN stoves
–
Instruction manual
63
A03
Pellet Tank Over-Temp.
- stove body overheating
- stove operating on maximum
power too long or is poorly
ventilated, i.e. warm air fan
operates on too low speed
1.
reset the alarm and restart
2.
reduce the stove heating power
and increase warm air fan speed
3.
clean the central flue gases
channel according to
chapter 6.7.
A04
Fumes Over-Temperature
- stove body overheating
- stove operating on maximum
power too long or is poorly
ventilated, i.e. warm air fan
operates on too low speed
1.
reset the alarm and restart
2.
reduce the stove heating power
and increase warm air fan speed
3.
clean the
central flue gases
channel
according to
chapter 6.8.
and the
plate in the firebox
-
Figures.45c
and
d
A05
Fumes Pressure Switch
Alarm
- flue gas channels or chimney
clogged
- chimney diameter larger than
prescribed
- firebox door open or the seal
damaged
- pellet feeder spiral clogged
- improperly executed
installation (chimney not
properly sealed)
- chimney is not insulated
according to the instructions
- burner pot improperly installed
into the casing
1.
reset the alarm and restart
2.
repeat ignition 4-5 times
3.
while the stove is shutting down
(flue gases fan rotating at maximum
speed), burn some paper and put a
fistful of pellets into the firebox to
warm the chimney
4.
check and clean the chimney and
flue gas channels
5.
connect the stove to a chimney
with prescribed diameter
6.
check the firebox door and replace
the gasket
7.
remove all the pellets from the
tank and clean the pellet feeder
spiral
8.
properly set the burner pot into the
casing
A06
Combustion Airflow Alarm
1.
reset the alarm and restart
2.
check burner pot cleaning / air
intake / chimney
A07
Door Open
- uncontrolled entry of air into
the firebox
- flue gas channels or chimney
clogged
- airflow sensor is polluted
1.
reset the alarm and restart
2
.
check if door is closed and
replace
the door gasket if necessary
4.
check and clean the chimney and
central flue gas channel -
chapter
6.7.
;
clean the sensor
-
chapter 6.9.
A08
Fumes Extractor Error
1.
reset the alarm and restart
2.
check and clean the chimney and
central flue gas channel -
chapter
6.7.
A09
Fumes Temp. Sensor Error
1.
reset the alarm and restart
2.
too low temperature of the
surrounding area
Summary of Contents for P 10 WATER+AIR Slim Modern
Page 1: ...INSTRUCTION MANUAL SN EN 719 PELLET STOVES SLIM MODERN P 8 AIR 8 kW P 10 WATER AIR 12 kW...
Page 14: ...SENKO pellet SLIM MODERN stoves Instruction manual 13 Figure 1a P 8 AIR SLIM MODERN...
Page 15: ...SENKO pellet SLIM MODERN stoves Instruction manual 14 P 10 WATER AIR SLIM MODERN Figure 1b...
Page 71: ...SENKO pellet SLIM MODERN stoves Instruction manual 70 Figure 43 a b c d e f g h...