Recommendations
:
activation and deactivation time intervals should include one day
only, from 00:00 to 24:00h, which means that the stove
can’t work
from Friday to Saturday, for instance
!
EXAMPLE:
start at 06:00 h
stop at 17:00 h
start at 21:00 h
stop at 05:00 h
the programme will use the lower value (05:00 h) as activation !
according to previous example,
the stop time must be greater than
start time!
before using the Chrono function, you should set the current day
and hour (if you still haven’t) following instructions in
chapter
5.4.1.
!
for the Chrono function to work, it needs not only be
programmed, but also activated (ENABLE) as shown in
figure 31
.
5.7.2.1. WEEKLY PROFILES
A group of 10 weekly profiles
(programmes) for quick setting of
on/off stove use times is available on
the control panel. Each profile is
defined with start/stop times per
particular days.
Once you have
selected a particular profile, you
can freely change all the parameters that define it.
You can see the
WRONG
SOLUTION:
Prog1
: Start 21:00, Stop 00:00
Prog2
: Start 00:00, Stop 05:00
Figure 33