SENKO pellet SLIM MODERN stoves
–
Instruction manual
10
1.1.
SAFETY DEVICES
SENKO pellet stove consists of the following safety devices:
Motherboard
intervenes directly and activates the alarm until
the stove completely cools off in operating conditions which deviate
from the pre-set safety conditions ;
Fuse
protects the stove from sudden changes in electricity
voltage (max.6,3 A and 250 V) - see
Figure 46
;
Pellet tank temperature safety probe
in the case of too high
pellet tank temperature
(max.110°C), the probe automatically
blocks pellet feeding and activates the alarm
A03
;
Water tank temperature safety probe
in the case of too high
boiler water te
mperature (max.95°C), the probe automatically
blocks pellet feeding and activates the alarm
A18
;
Flue gases temperature measurement probe
in case of
excessive flue gases temperature (max.22
0°C) the probe
automatically resets the stove to normal temperature values
(minimum power
– level 1, i.e.
fire 1
on the control panel) OR
activates the alarm
A04
;
Room temperature measurement probe
in case of higher
room temperature from the set point the probe automatically resets
the stove to normal temperature values (minimum power
– level 1,
i.e.
fire 1
on the control panel) - see
Figure 28
;
Primary combustion air flow measurement probe
in case of
insufficient
(or
excessive)
chimney
diameter,
this
probe
automatically regulates (to a certain level) the speed of flue gases
ventilator, i.e. primary air flow, in order to achieve optimum fuel
combustion in the firebox.
Summary of Contents for P 10 WATER+AIR Slim Modern
Page 1: ...INSTRUCTION MANUAL SN EN 719 PELLET STOVES SLIM MODERN P 8 AIR 8 kW P 10 WATER AIR 12 kW...
Page 14: ...SENKO pellet SLIM MODERN stoves Instruction manual 13 Figure 1a P 8 AIR SLIM MODERN...
Page 15: ...SENKO pellet SLIM MODERN stoves Instruction manual 14 P 10 WATER AIR SLIM MODERN Figure 1b...
Page 71: ...SENKO pellet SLIM MODERN stoves Instruction manual 70 Figure 43 a b c d e f g h...