Pressure that facilitates chimney function can occur in rooms directly
exposed to the wind (B), but it can also adversely affect the chimney
through external pressure if the chimney is situated on the side exposed to
wind (A). Contrary to that, underpressure can occur in lee rooms (C),
adversely affecting functions of the chimney situated on the opposite side
(D) from the wind direction.
4.6.
CENTRAL HEATING SYSTEM CONNECTION
Prior to commencing the firing procedure
, the stove must be
connected to the central heating system and the
boiler must be filled with
water
.
①
CONNECTIONS TO THE SYSTEM
The pipe installation
must be executed in accordance with valid
technical regulations
and DIN 4751 norm
– part 1 for open systems and
DIN 4751
– part 2 for closed systems, following
professional standards
,
and
only by an authorized expert
.
It is not allowed
to reduce the pipe diameter connecting the boiler to the
heating installation connection point. Otherwise, the warranty will be void.
Prior to connecting the boiler to the heating installation,
the pipelines
are to be thoroughly cleansed from potential filth sediments
. This
prevents boiler overheating, system noise, pump malfunctions and mixing
valve malfunctions.
Descending
wind
wind
A
B
C
D
A-B
zones in overpressure
C-D
zones in underpressure
Figure 16
only at
P-10
stove!
Summary of Contents for P 10 WATER+AIR Slim Modern
Page 1: ...INSTRUCTION MANUAL SN EN 719 PELLET STOVES SLIM MODERN P 8 AIR 8 kW P 10 WATER AIR 12 kW...
Page 14: ...SENKO pellet SLIM MODERN stoves Instruction manual 13 Figure 1a P 8 AIR SLIM MODERN...
Page 15: ...SENKO pellet SLIM MODERN stoves Instruction manual 14 P 10 WATER AIR SLIM MODERN Figure 1b...
Page 71: ...SENKO pellet SLIM MODERN stoves Instruction manual 70 Figure 43 a b c d e f g h...