Instruction manual
31
IT IS STRONGLY RECOMMENDED TO WASH THE ENTIRE SYSTEM
BEFORE CONNECTING IT IN ORDER TO GET RID OF POSSIBLE
RESIDUES AND DEPOSITS
.
The connection
to the heating system
is executed via union flat joint,
with OR without the mixing valve
onto a closed or open system.
Connect the stove USING FLEXIBLE PIPES so that the stove is not
too strictly connected to the system, and to allow slight movements
.
THE STOVE IS FACTORY SET TO CONNECT TO THE CLOSED
CENTRAL HEATING
SYSTEM
!
Regardless of the expansion tank
(located beneath the left side panel)
built-in pellet stove, central heating system must also have its own
expansion tank, adjusted to the expansion tank in the stove.
The stove is equipped as standard with a
safety valve 2 bar
(located
beneath the left side panel).
An outlet of the safety valve MUST be
carried out into the sewer
. The water drain pipe must be adequate to
support the water’s high temperature and pressure.
It is necessary to
install the vent valve
(regardless of the valve built-in
stove)
at the highest point of the installation
. When filling the boiler and
the radiator system it is necessary to open the mixing valve, if one had
been installed;
adequately deaerate the boiler and the heating system
.
In places of any connection points on the stove (water, chimney,
air inlet
…), inspection hatches must be installed for system
maintenance and servicing purposes. Also, YOU SHOULD ADHERE
TO THE SAFETY DISTANCES (
see
Figure 3
)
.
Summary of Contents for P 10 WATER+AIR Slim Modern
Page 1: ...INSTRUCTION MANUAL SN EN 719 PELLET STOVES SLIM MODERN P 8 AIR 8 kW P 10 WATER AIR 12 kW...
Page 14: ...SENKO pellet SLIM MODERN stoves Instruction manual 13 Figure 1a P 8 AIR SLIM MODERN...
Page 15: ...SENKO pellet SLIM MODERN stoves Instruction manual 14 P 10 WATER AIR SLIM MODERN Figure 1b...
Page 71: ...SENKO pellet SLIM MODERN stoves Instruction manual 70 Figure 43 a b c d e f g h...