Operating manual for the VISATRON VN2020
V2.0 12/2021 EN
Page
8
of
106
SCHALLER AUTOMATION
66440 Blieskastel / Saarland / Germany / Industriering 14 / P.O. Box 1280
Industrielle Automationstechnik GmbH & Co. KG
T
el. +49(0)6842-508
-
0
/ Fax -260 / Email: [email protected] /
www.schaller-automation.com
Mechanical interfaces
Dimensions
Approx. 539 x 298 x 171 mm
Weight
12.41 kg
M1
External thread M16x1.5
Pipe connection, diameter size 10
M2
External thread M30x2
Pipe connection, diameter size 22
M3
External thread M30x2
Pipe connection, diameter size 22
M4
Internal thread G1/4
M5
x4 through holes for screws M8
Electrical interfaces
Power supply
18 - 31.2 V DC
Nominal voltage
24 V DC
Current consumption
Maximum 2 A
Supply E1
24 V DC
M25: Cable diameter 8-16 mm
Earthing via holes in base plate during
installation
Supply E2
M20: Cable diameter 5-13mm
Relay outputs
2 ×
“High Oil Mist Alarm”
1 ×
“Ready” (ready for operation)
1 ×
“Oil Mist Pre-Alarm”
(max. 60 Volt AC/DC, 1A)
Communication interface with monitoring
device
3-wire RS485, electrically isolated/
CANopen, electrically isolated
Recommended communication cable
LAPP UNITRONIC-FD CP (TP) plus
UL-CSA CABLE