Operating manual for the VISATRON VN2020
V2.0 12/2021 EN
Page
19
of
106
SCHALLER AUTOMATION
66440 Blieskastel / Saarland / Germany / Industriering 14 / P.O. Box 1280
Industrielle Automationstechnik GmbH & Co. KG
T
el. +49(0)6842-508
-
0
/ Fax -260 / Email: [email protected] /
www.schaller-automation.com
4.6. Hose lines
Hose lines can also be used as an alternative to the suction and exhaust air pipes.
The hose lines used by Schaller Automation consist of a hydraulic hose with an additional
coating of galvanised wire mesh.
Figure 8: Hose line with wire mesh
The hose lines are available with certificates from classification societies and authorities. The
certificates can be downloaded from Schaller Automation
’s homepage (www.schaller-
automation.com).
4.7. Canister siphon
During the suction process for an atmosphere containing oil mist, oil may settle in the suction
lines.
The canister siphon has the task of draining this settled oil in the header pipes before it clogs
or constricts the pipes.
Figure 9: Canister siphon
At least two canister siphons are therefore required per installation kit.