Pneumatic interfaces
P1
External thread M16x1.5
Pipe connection, diameter size 10
Compressed air supply
Min. 2 bar
Max. 14 bar
Compressed air consumption
1.2 nm³/h ± 10%
Value may vary depending on customer
solution
Negative pressure
Position M4
Measure and adjust negative pressure
Min. -55mmH2O (-5.5 mbar)
Nom. -60mmH2O (-6 mbar)
Max. -65mmH2O (-6.5 mbar)
Air quality
ISO 8573-1:2010 - 6-4-4
Environmental conditions
Operating temperature
5 to 70 °C
Storage temperature range
-25 to 80 °C
Relative humidity
up to 95%
Protection rating
IP 54
Vibrations
5 - 25 Hz:
1.6mm peak
25 - 100 Hz: 40m/s² peak