3-24
Control of 3-WAY ECO-i SYSTEM
1
2
3
4
5
6
7
8
2. Wireless Remote Controller
2-22. Setting Address Switches
When more than one receiver and remote control are installed in the same room, setting up addresses allows
them to avoid interfering with each other.
Refer to the Users Manual for information on how to change the addresses of the remote controls.
Changing the address of a receiver can be done after removing the screw to the receiver’s PCB cover. Once the
change is complete, put the cover back in place; while holding the wiring with the cable clamp, tighten its screw.
Address Display
on the Remote
Control
Position of the
Receiver’s
Address Switch
It doesn’t matter
where the Receiver’s
Address Switch is.
1 2 3
4 5 6
4 5 6
1 2 3
4 5 6
1 2 3
(1)
Remove the face plate of the receiver’s PCB and turn the DIP switch to RUN/On (Down Up) and operate the
wireless remote control with its Start/Stop button.
(2)
During a test run, all display lamps on the display will light up.
(3)
During a test run, it is not possible to adjust the temperature.
(4)
After completing a test run, be absolutely sure to return the Test Run switch to OFF (Up Down) and make sure
none of the display lamps are blinking. Also, put the face plate back in place.
2-23. Test Operation
1.
This is hard on the device, so only use this for the test run.
2.
After turning on the power, the unit will not receive any commands from the remote control for about 1 minute.
This is not an error. (In fact it does receive signals, but they are cancelled.)
3.
Make sure to operate while the indoor unit is stopped.
4.
The address of indoor unit is set to "ALL" at the time of the shipment.
NOTE
TD831143-00̲W-3WAY.indb 24
TD831143-00̲W-3WAY.indb 24
2008/12/01 10:26:26
2008/12/01 10:26:26
Summary of Contents for SPW-C0705DZH8
Page 2: ...i ...
Page 3: ...ii ...
Page 52: ...2 42 MEMO ...
Page 158: ...3 106 MEMO ...
Page 528: ...4 370 MEMO ...
Page 562: ...6 18 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW KR254GXH56 A B ...
Page 575: ...6 31 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR254GXH56 A B ...
Page 577: ...6 33 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR364GXH56 A B ...
Page 579: ...6 35 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR484GXH56 A B ...
Page 581: ...6 37 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR764GXH56 A B ...
Page 583: ...6 39 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR964GXH56 A B ...
Page 589: ...6 45 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW GU055 075 105XH ...
Page 590: ...6 46 MEMO ...
Page 702: ...8 96 MEMO ...
Page 703: ...SANYO Electric Co Ltd Printed in Japan 200812B DC ...