(5)
ON
OFF
(1)
(2)
(3)
(4)
Explain to the customer the methods for use of the system, as described in the Operation Manual.
After work is completed, present the Operation Manual and Information for the Person in Charge of Installation
(Electrical) Work to the customer.
Explanation to Customers
After checking the addresses and operating the units, press and hold the button for 2 seconds or
longer. The schedule timer display returns to the normal display and all controllable indoor units stop.
With the selected timer group displayed, press the timer button. Each time the button is pressed the
indoor units in the displayed timer group start or stop. Pressing the button in this mode permits all
items (operation start/stop, operation mode, temperature setting items) at the indoor units in the displayed
timer group where remote controller prohibit is in effect.
Use the GROUP button in the area to display the blinking central control addresses in sequential order. In
this way, it is possible to check which central control addresses in the displayed timer group can be operated
by the timer.
Press and hold the schedule timer button, button, and CLEAR button for 4 seconds or longer.
“Ad-(central control address)” appears in sequence, blinking.
The schedule timer communicates with the indoor units to check which central control addresses can be
controlled with the current timer control. The schedule timer can then be used to start and stop these units.
Checking the Central Control Addresses and Operating the Units that are Controlled
by the Schedule Timer
Backup battery
Backup switch
After installation is completed, check that the backup switch on the reverse side of the schedule timer PCB is
turned to ON.
(The backup battery will retain the current time for up to 100 hours.)
Memory Backup Switch
Repeat steps (3) – (4) for each timer group. When registration is completed, press the timer button.
The schedule timer restarts automatically and performs initial communications. (SCAn blinks in the display.)
The normal display appears after several minutes, and the manually assigned timer group settings are con-
firmed.
To continue registering addresses, repeat step (3). (Central control address numbers will be added to the right
side of the LCD display.) To cancel a registered central control address, use the button in the area to
select the timer group, then use the button in the area to select the central control address and press the
button.
(4)
3-93
Control of 3-WAY ECO-i SYSTEM
1
2
3
4
5
6
7
8
5. Schedule Timer
TD831143-00̲W-3WAY.indb 93
TD831143-00̲W-3WAY.indb 93
2008/12/01 10:26:48
2008/12/01 10:26:48
Summary of Contents for SPW-C0705DZH8
Page 2: ...i ...
Page 3: ...ii ...
Page 52: ...2 42 MEMO ...
Page 158: ...3 106 MEMO ...
Page 528: ...4 370 MEMO ...
Page 562: ...6 18 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW KR254GXH56 A B ...
Page 575: ...6 31 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR254GXH56 A B ...
Page 577: ...6 33 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR364GXH56 A B ...
Page 579: ...6 35 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR484GXH56 A B ...
Page 581: ...6 37 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR764GXH56 A B ...
Page 583: ...6 39 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW DR964GXH56 A B ...
Page 589: ...6 45 Electrical Data 1 2 3 4 5 6 7 8 2 Indoor Unit Schematic Diagram SPW GU055 075 105XH ...
Page 590: ...6 46 MEMO ...
Page 702: ...8 96 MEMO ...
Page 703: ...SANYO Electric Co Ltd Printed in Japan 200812B DC ...