SANY LATIN AMERICA
7-35
SY195/205/215/225C9 Crawler Hydraulic Excavator
Troubleshooting
Shop Manual - June 2013
User Code
Service Code
Trouble
Internal temperature of controller is abnormal. Engine
acceleration fails and the machine acts slowly.
16
E116
Failure description
Internal temperature of controller keeps above 80°C or below -30°C for 10 sec-
onds when the power is on.
Response from controller The controller stops the motor and the solenoid coil.
Symptom of machine
Engine acceleration fails and the machine acts slowly.
Possible causes and standard value in nor-
mal state
Cause
Standard value in normal state/Remarks on troubleshooting
1
Internal
failure of
controller
No troubleshooting can be done for failure occurs in the inner of controller. (If this
failure occurs, replace the controller.)
2
3
4
5
E116 (controller internal temperature abnormal)
https://www.tractormanualpdf.info/