SANY LATIN AMERICA
7-42
SY195/205/215/225C9 Crawler Hydraulic Excavator
Troubleshooting
Shop Manual - June 2013
User Code
Service Code
Trouble
Reading of boom-raise pilot pressure is abnormal.
Only output alarm is enabled. .
24
E324
Failure description
A pressure feedback voltage other than 0.25 – 4.75V keeps more than
200msec when the power is on.
Response from controller Only output alarm is enabled.
Symptom of machine
Boom-raise motion is slow.
Possible causes and standard value in normal state
Cause
Standard value in normal state/Remarks on troubleshooting
1
Failure of 5V
power supply
●
Turn engine start switch to OFF position. Then, keep it at ON position to
perform troubleshooting.
Between CN-126M A and B
Voltage
About 5V
2
Open circuit
of signal wire
●
Turn engine start switch to OFF position. Keep it at OFF position to perform
troubleshooting.
Between CN-126M C and 70 pin of controller
Resistance
≤
1
Ω
Between CN-126M B and ground
≤
1
Ω
3
Short circuit
of signal wire
(grounded)
●
Turn engine start switch to OFF position. Keep it at OFF position to perform
troubleshooting.
Between CN-126M C and ground
Resistance
≥
2M
Ω
4
Failure of
sensor
●
Turn engine start switch to OFF position. Then, keep it at ON position to
perform troubleshooting.
Between CN-126M C and ground
Voltage
0.5±0.2V
5
70
54
56
C
B
A
CN-126M
206#
00#
50#
ZX215-1005078
5 V
SIGNAL
CONTROLLER
GND WIRE
5V
PWR SUPPLY
GND WIRE
CAB
CHASSIS HARNESS
BOOM-RAISE PILOT
PRESS. SENSOR
BOOM-RAISE PILOT PRESS.
SIGNAL COLLECTING PORT
E324 (abnormality in boom-raise pilot pressure)
https://www.tractormanualpdf.info/