SY195/205/215/225C9 Crawler Hydraulic Excavator
Troubleshooting
Shop Manual - June 2013
User Code
Service Code
Trouble
Abnormal output of power supply in sensor
17
E017
Failure description
The controller detects out over current or short circuit of sensor power source
output when the power is on.
Response from controller Only output alarm is enabled.
Symptom of machine
—
Possible causes and standard value in normal
state
Cause
Standard value in normal state/Remarks on troubleshooting
1
Short circuit
in harness
(grounded)
●
Turn engine start switch to OFF position. Keep it at OFF position to perform
troubleshooting.
Measure the resistance between pin 56, pin 75, pin 74 of
controller KC-MB and the ground.
Resistance
≥
2M
Ω
2
Internal
failure of
controller
No troubleshooting can be done for failure occurs in the inner of controller. (Except
for the above reasons, the controller must be replaced in case of failure.)
3
4
5
E017 (abnormal output of 5v power supply in sensor)