SANY LATIN AMERICA
7-85
SY195/205/215/225C9 Crawler Hydraulic Excavator
Troubleshooting
Shop Manual - June 2013
E-18 Incorrect arm-out pilot pressure reading
Trouble
Reading of arm-out pilot pressure is incorrect.
Related information
Possible causes and standard value in normal
state
Cause
Standard value in normal state/Remarks on troubleshooting
1
Failure of 5V
power supply
●
Turn engine start switch to OFF position. Then, keep it at ON position to
perform troubleshooting.
Between CN-122M
①
and
③
Voltage
About 5V
2
Open circuit of
signal wire
●
Turn engine start switch to OFF position. Keep it at OFF position to per-
form troubleshooting.
Between CN-122M
②
and controller pin 52
Resistance
≤
1
Ω
3
Short circuit of
signal wire
●
Turn engine start switch to OFF position. Keep it at OFF position to per-
form troubleshooting.
Between CN-122M
②
and ground
Resistance
≥
2M
Ω
4
Failure of sen-
sor
●
Turn engine start switch to OFF position. Then, keep it at ON position to
perform troubleshooting.
Between CN-122M
②
and ground
Voltage
0.5V~ 4.5V
5
CN-122M
(
DF-3
)
2
3
1
75
55
52
ZX215-1005109
5V
CHASSIS HARNESS
CAB
ARM OUT
PRESS SENSOR
SIGNAL
GND WIRE
CONTROLLER
SENSOR 5V
SENSOR GND WIRE
ARM OUT
PRESS SENSOR
https://www.tractormanualpdf.info/