SANY LATIN AMERICA
4-161
SY195/205/215/225C9 Crawler Hydraulic Excavator
Structure and Function
Shop Manual - June 2013
1) Battery
relay
2) Battery
3) Engine start switch
4) Fuel control dial
5) Start
motor
6) Engine
controller
7) Fuel injection pump
8) Throttle
motor
9) Shutdown
device
ZX215-1002176
4
3
2
5
9
1
Z
8
7
6
Outline
●
Start and stop the engine only with the en-
gine start switch (3).
●
The controller (6) receives the signal from
the fuel control dial (4) and transmits the
drive signal to the throttle motor (8) to
control the governor lever angle of fuel
injection pump (7) and control the engine
speed.
●
When engine start switch (3) is turned to
the OFF position, the shutdown device (9)
pulls the flame-out arm on the injection
pump to the “parking” position and cuts the
engine fuel supply. Then, the engine stops.
4.8
Engine Control
https://www.tractormanualpdf.info/