SANY LATIN AMERICA
8-166
SY195/205/215/225C9 Crawler Hydraulic Excavator
Disassembly and Assembly
Shop Manual - June 2013
4. Fuel level sensor - check
●
Swing the float up and down in order
to measure the effective angle of radial
swing, i.e. the line through the
fl
oat and the
turning point will swing 105°.
●
Swing the
fl
oat up and down. The vertical
distance between the upper limit and the
lower limit of the
fl
oat should be 500 mm.
●
Move the float to its upper limit. Measure
the resistance between the sensor terminal
R and ground with a multimeter. The mea-
sured resistance should be Ru 9.6
Ω
.
●
Move the float to its lower limit. Measure
the resistance between the sensor terminal
R and ground with a multimeter. The mea-
sured resistance should be Rd 86
Ω
.
3. Pressure sensor - check
●
Input volt: 4.75~5.25VDC
●
Output volt: 0.5~4.5V
●
Pressure range: 0~50BAR
ZX215-1006319
Float
Lever
Casing
Ternimal R
Connector
https://www.tractormanualpdf.info/