SANY LATIN AMERICA
6-7
SY195/205/215/225C9 Crawler Hydraulic Excavator
Testing and Adjusting
Shop Manual - June 2013
2. Measure with an opacimeter
1) Mount the opacimeter onto the exhaust
pipe by clamping it to the pipe outlet.
ZX215-1004003
ZX215-1004004
2) Open the opacimeter and preheat it for
about 15 minutes.
3) Start the engine and keep the engine
running until engine coolant tempera-
ture is within the operational range.
4) When engine speed increases sud-
denly or is kept at high idle, use the
opacimeter to read the smoke value of
exhaust gas.
5) Remove the testing tools after measur-
ing. Make sure the machine goes back
to its normal state.