SANY LATIN AMERICA
4-192
SY195/205/215/225C9 Crawler Hydraulic Excavator
Structure and Function
Shop Manual - June 2013
4.9.11 Electrical Components
Operation
●
The relationship between the pressure ap-
plied on the sensor (P) and output voltage
(E) is shown in the right diagram.
ZX215-1002209
(V)
(MPa)
Sensor output voltage (E)
Oil pressure (P)
4.9.11.1 Pump pressure sensor
ZX305-1002066
A
B
C
Terminal A
Terminal B
Terminal C
Connection diagram
Signal name
PWR +5V
Output