SANY LATIN AMERICA
4-155
SY195/205/215/225C9 Crawler Hydraulic Excavator
Structure and Function
Shop Manual - June 2013
●
Refrigerant not circulating
Symptom: Non-refrigeration (intermittent refrigeration)
Symptom
Cause
Analysis
Remedy
●
Vacuum at Lo-pres-
sure side; pressure
at Hi-pressure side
extremely low
●
Frosting or conden-
sation on the pipes
around the expan-
sion valve or receiv-
er/dehydrator
●
Moisture or contami-
nant in the refrigerant
hinders the
fl
ow of
refrigerant.
●
Air leak at the thermal
pipe of the expansion
valve hinders the
fl
ow
of refrigerant.
●
Refrigerant not
circulating
●
Check the expansion valve
and ERP.
●
Blow the contaminant in the
expansion valve or replace
the expansion valve if nec-
essary.
●
Replace the receiver
●
Release internal air and
add refrigerant. If air leaks
from thermal pipe, replace
expansion valve.
ZX215-1002171