Machine Controls
SY135C Excavator
3-46
Operation and Maintenance Manual — 0120
SANY
System Information Screen
0004114
Fig. 3-55
1
Press the F5 function button (1) on the home screen to
access the System Information screen.
Access to the System Information screen (2) requires
entering a password. The operator can access the main
screen by entering the password 31868.
The F3 function button (11) can be pressed to directly
access the System Time Calibration screen without
entering the password. See “System Time Display” on
page 3-47.
To enter the password (3):
1. Press the F1 function button (9) as needed to select
the proper number.
2. Use the F2 function button (10), the right arrow
function button (7), or the left arrow function button
(8) to index to the next position.
3. Repeat steps 1 and 2 for each number.
4. Press the Enter function button (6) to enter the
password.
NOTE:
The F4 function button (4) is for factory
use only.
Press the F5 function button (5) to return to the previous
screen.
0000540
Fig. 3-56
2
3
9
7
8
6
4
5
10
11