Hydraulic Breaker Maintenance Interval
Hydraulic oil breaks down faster on machines equipped with a hydraulic breaker than on machines equipped with a
bucket. Change the hydraulic oil and filters every 400 hours on breaker-equipped machines. See “Change the
Hydraulic Oil” on page 5-75.
NOTICE!
The hydraulic oil filter must be replaced after 250 hours with a breaker operating rate above
50%. Failure to follow this notice, could result in damage to the machine.