Maintenance
SY135C Excavator OMM
5-34
Operation and Maintenance Manual — 0120
SANY
Check the Engine Primary Air Filter System
1. Prepare the machine for service. See “Maintenance
2. Open the left rear access door. See “Left Rear Access
3. Squeeze the dust evacuator (1) mounted on the end cap
(2) of the filter housing to release any dust or debris.
4. Check the condition of the dust evacuator and replace
if required.
NOTE:
If the dust evacuator is cracked, torn, remains
open, or is missing, dust particles that are
normally expelled can collect on the filter and
will shorten air filter service life.
5. Release three latches (3) and remove the air filter end
cap.
Fig. 5-82
0004112
2
1
Fig. 5-83
0004113
Fig. 5-84
0004112
3
3
3