![SANY SY135C Operation And Maintenance Manual Download Page 192](http://html.mh-extra.com/html/sany/sy135c/sy135c_operation-and-maintenance-manual_1198261192.webp)
Maintenance
SY135C Excavator OMM
5-50
Operation and Maintenance Manual — 0120
SANY
Fuel System
Drain the Fuel Tank
NOTE:
Use diesel fuel to clean the inside of the fuel
tank.
1. Prepare the machine for service. See “Maintenance
NOTE:
See page 5-12 for the fluid capacity of the fuel
system.
2. Swing the upper structure to access the fuel tank drain
valve.
3. Place a suitable container under the fuel tank to collect
drained fuel.
4. Open the shutoff valve (1) to drain water and sediment
accumulated on the bottom of the tank. Do not allow fuel to splash out of the container.
5. Close the shutoff valve when clean fuel drains from the fuel tank.
6. Add fuel to the fuel tank as necessary.
7. Start the engine and allow it to run at idle speed.
8. Check the fuel shutoff valve for leaks. Contact a SANY dealer if repairs are necessary.
NOTICE!
Dispose of contaminated fuel or water in accordance with all applicable environmental
regulations.
Failure to follow this notice could result in damage to the environment.
Fig. 5-107
0004155
1