CHAPTER 3. Data Network Function
© SAMSUNG Electronics Co., Ltd.
page 116 of 689
point-to-point Specify OSPF point-to-point network
point-to-multipoint
Specify OSPF point-to-multipoint network
WEC8500/configure/interface ge2# ip ospf network
Authentication configuration
This is CLI that selects whether to use user authentication.
WEC8500/configure/interface ge2# ip ospf authentication ?
message-digest Use message-digest authentication
null Use null authentication
<cr>
WEC8500/configure/interface ge2# ip ospf authentication message-
digest ?
<cr>
WEC8500/configure/interface ge2# ip ospf authentication null ?
<cr>
WEC8500/configure/interface ge2# ip ospf authentication null
OSPF Cost configuration
Enter a cost value between 1 and 65535.
WEC8500/configure/interface ge2# ip ospf cost ?
1 - 65535
Cost
WEC8500/configure/interface ge2# ip ospf cost 2 ?
<cr>
DATABASE-FILTER configuration
WEC8500/configure/interface ge2# ip ospf database-filter ?
all Filter all LSA
WEC8500/configure/interface ge2# ip ospf database-filter all ?
out Outgoing LSA
WEC8500/configure/interface ge2# ip ospf database-filter all out ?
<cr>
WEC8500/configure/interface ge2# ip ospf database-filter all out
Dead-interval configuration
The default value of dead-interval is 4 times of hello-interval. Because the default
hello-interval is configured to 10 sec., the dead-interval will be 40 seconds if the hello-
interval is not configured. In addition, operator can change it to a value between 1
second and 65535 seconds.
WEC8500/configure/interface ge2# ip ospf dead-interval ?
1 - 65535
Seconds