15.5 AC ELECTRICAL CHARACTERISTICS
Table 15-4. Operating Frequency
Characteristic
Min
Max
Units
Core frequency
33
166
MHz
System bus frequency
33
133
MHz
USB Frequency
48
48
MHz
Table 15-5. Clock AC timing specification
Characteristic
Min
Max
Units
Internal PLL lock time
–
150
µ
s
Frequency of operation (XCLK)
–
133
MHz
XCLK cycle time
7.5
–
ns
XCLK duty cycle
45
55
%
Frequency of operation (HCLKO)
–
133
MHz
HCLKO cycle Time
7.5
–
ns
HCLKO duty cycle
45
55
%