32-BIT TIMERS
S3C2501X
14-2
14.3 INTERVAL MODE OPERATION
In interval mode, a timer generates one-shot pulse of preset timer clock duration whenever a time-out occurs.
This pulse generates a time-out interrupt that is directly output at the timer's configured output pin (TOUTn). In
this case, the timer frequency monitored at the TOUTn pin is calculated as:
f
TOUT
= f
SYSCLK
/ Timer data value, where f
SYSCLK
is the system bus clock frequency.
14.4 TOGGLE MODE OPERATION
In toggle mode, the timer pulse continues to toggle whenever a time-out occurs. An interrupt request is generated
whenever the level of the timer output signal is inverted (that is, when the level toggles). The toggle pulse is
output directly at the configured output pin. Using toggle mode, you can achieve a flexible timer clock range with
50% duty. In toggle mode, the timer frequency monitored at the TOUTn pin is calculated as follows:
f
TOUT
= f
SYSCLK
/ (2
×
Timer data value)
f
TOUT
f
TOUT
Time-out
Time-out
Time-out
Interval Mode
Toggle Mode
(Initial TOUTn is 0)
Time-out
Time-out
Time-out
Figure 14-1. Timer Output Signal Timing