![Samsung NX-1232 Technical Manual Download Page 118](http://html.mh-extra.com/html/samsung/nx-1232/nx-1232_technical-manual_351250118.webp)
DISPLAY
DESCRIPTION
D E F A U L T
RANGE
DOR R OFF
controls the duration of ringing at the door
030SEC 1~250SEC
(Door Ring
ring destination before canceling
OFF time)
FIRST DGT
controls how long the system will wait for
025SEC 1~250SEC
(First Digit
dialing to begin before dropping the dial tone
wait time)
and initiating an error tone.
HOOK OFF
controls the time before dial tone is sent to a
0200MS
100~
(Hook OFF
single-line station.
2500MS
time)
INTER DGT
controls the grace period between dialing
025SEC 1~250SEC
(Inter Digit
valid digits before dropping the call and
duration)
returning the user back to an error tone.
MMC OUT
controls the grace period between programming
030SEC 1 0 ~ 2 5 0 S E C
(MMC
actions while in a programming session, before
session time)
returning system to secure programming status.
OFF R INT
controls the duration of time between ring
015SEC 1~250SEC
(Off hook
bursts to a user who has a camped-on call.
Ring Interval)
PAGE MAX
controls the allowed duration of a page
020SEC 1~250SEC
(Page duration) announcement.
RCAL DISC
this is the time an attendant recall will
002MIN 1~250MIN
(Recall
ring before being disconnected.
Disconnect
time)
RCAL RING
this is the length of time a transfer recall
015SEC 0~250SEC
(Recall Ring
will ring at a station before recalling the
length)
operator
RCAL WAIT
after a transferred call is recalling at the transferring 015SEC 0~250SEC
(Recall
station and the station is busy, this timer will expire
Waiting time)
and transfer the call to the operator.
This only applies to trunk calls.
RCAL HOLD
determines the time calls can be left on hold
045SEC 0~250SEC
(Recall Hold
before recalling back to the holding station.
time)
RCAL TRSF
determines the time transferred calls ring
045SEC 0~250SEC
(Recall
before recalling.
Transfer time)
SLT F MIN
monitors the duration of a hookswitch flash to ensure that
0350MS
100~
(minimum SLT
the flash is valid and not a line transient or accidental
2500MS
Flash time)
hookswitch bounce. It is the minimum time of single-line station.
SLT F MAX
maximum time of hookswitch flash of a
0800MS
100~
(maximum SLT
single-line station.
2500MS
flash time)
SMDR PULS
this grace period timer starts SMDR recording
030SEC 1~250SEC
(SMDR start
for pulse (rotary) dialing and controls the
time for rotary LCD duration timer on the keysets.
dialing)
SMDR DTMF
this grace period timers starts SMDR recording
015SEC 1~250SEC
(SMDR start
for DTMF (Touch Tone) dialing and controls
time for touchtone the LCD duration timer on the keysets.
dialing)
TRK DISC
controls the duration of an outside call
030MIN 1~250MIN
NX-SERIES
HYBRID KEY SYSTEM
PROGRAMMING SECTION
MMC 50
4Programming 1999.9.15 12:43 PM 페이지49
Summary of Contents for NX-1232
Page 1: ...NX SERIES Technical Manual NX 308 NX 820 NX 1232 표지 1999 9 15 12 40 PM 페이지1 ...
Page 3: ...0preface 1999 9 15 12 46 PM 페이지2 ...
Page 5: ...0preface 1999 9 15 12 46 PM 페이지4 ...
Page 6: ...GENERAL DESCRIPTION SECTION 1GENERAL 1999 9 15 12 46 PM 페이지1 ...
Page 7: ...1GENERAL 1999 9 15 12 46 PM 페이지2 ...
Page 20: ...INSTALLATION SECTION 2INSTALL 1999 9 15 12 45 PM 페이지1 ...
Page 21: ...2INSTALL 1999 9 15 12 45 PM 페이지2 ...
Page 40: ...FEATURES SECTION 3feature 1999 9 15 12 44 PM 페이지1 ...
Page 41: ...3feature 1999 9 15 12 44 PM 페이지2 ...
Page 70: ...PROGRAMMING SECTION 4Programming 1999 9 15 12 42 PM 페이지1 ...
Page 71: ...4Programming 1999 9 15 12 42 PM 페이지2 ...
Page 145: ...NX SERIES HYBRID KEY SYSTEM PROGRAMMING SECTION 4Programming 1999 9 15 12 44 PM 페이지76 ...
Page 147: ...5APPENDIX 1999 9 15 12 41 PM 페이지2 ...
Page 158: ...BACK UP DATA SHEETS 6BACK_UP 1999 9 15 12 40 PM 페이지1 ...
Page 159: ...6BACK_UP 1999 9 15 12 40 PM 페이지2 ...
Page 161: ...6BACK_UP 1999 9 15 12 40 PM 페이지4 ...
Page 172: ...CODE GA68 60655A Edition 05 DN April 1999 Printed In Korea 표지 1999 9 15 12 40 PM 페이지2 ...