13.2.3.2 Input Load
Each listener draws less than 2 mA @ 2 V input voltage.
13.2.3.3 Termination
The R5 NAV Junction Box has built in termination resistors. If needed, the termination
resistors can be connected by flipping the respective termination switch in the junction
box. If the junction box is not used, a 1kΩ termination resistor can be used close to the
receiver end.
13.2.3.4 Schematics
Each of the RS-422 serial interfaces on the R4 Navigation Sensor fulfils the
requirements as specified in IEC 61162-1. In addition, User Port 1 supports a
communication rate up to 38400 bps and User Port 2 up to 19200 bps.
Figure 111 - R4 Navigation Sensor Serial Interface Input Schematics
Figure 112 - R4 Navigation Sensor Serial Onterface Output Schematics