ETHERLINK II - Repeater
Manual
Page 62 of 106
-
Data are not received
Power backoff
N
Output signal power [dBm]
Far end power
backoff
N
Receiver gain [dBm] (in the current version invalid values are
displayed)
Loop attn
N
Attenuation in the loop [dB]
NMR
N
Maximum possible increase in the noise margin for which the BER
is expected to be no less that 10
-7
[dB]
Bitrate
N
Data transmission rate in the xDSL line [kbit/s]
Temperature
N
Unit temperature [С
] (only for SubRack devices)
Powermode
P0
P1
P2
P3
P4
P5
CPU clock frequency is 50MHz.
CPU clock frequency is 50MHz smart start
CPU clock frequency is 25MHz smart start
CPU clock frequency is 10MHz smart start
CPU clock frequency is 5.5MHz smart start
CPU clock frequency is 5.5MHz smart start
4.6.4.4 <STATUS ETH> command
The <STATUS> command displays parameters of the Ethernet port (ETH1
– ETH4), namely the
rate and the operation mode:
Ethernet port speed/duplex: 100 FULL
RR_01_FMM>
4.6.4.5 <MACTABLE> command
The <MACTABLE> displays the dynamic table of MAC addresses:
CO_FMM>MACTABLE
I/F VID MAC I/F VID MAC
LAN 1 00:0c:6e:ea:ee:4a LAN 1 00:c0:26:a3:6e:a2
LAN 1 00:c0:26:31:66:3e LAN 1 00:0c:f1:6e:19:8c
LAN 1 00:0f:24:b5:65:d0 LAN 1 00:1f:00:00:01:eb
LAN 1 02:01:00:00:00:00 LAN 1 00:c0:df:0e:b5:40
LAN 1 00:80:48:15:72:0b LAN 1 00:05:5d:c7:e6:8f
LAN 1 00:c0:26:a3:65:32 LAN 1 00:c0:26:a7:cd:13
LAN 1 00:c0:26:31:5d:61 LAN 1 00:80:48:15:d3:06
LAN 1 00:c0:26:31:65:07 LAN 1 00:08:0d:b1:e9:fa
CO_FMM>
Option: С – update the table continuously.
Definitions:
I/F
– the name of the port from which an Ethernet packet was transmitted to the internal switch.
VID
– VLAN ID (VLAN number) transmitted to the internal switch of the Ethernet packet.
MAC
– MAC address of the sender of the Ethernet packet.