14
en | Cabling
DBP Digital Beltpack
2021-06 | 01 | F.01U.380.825
Technical Manual
Bosch Security Systems, LLC
i
Notice!
It is possible to use PoE injectors on the end of a daisy chain to extend the number of DBPs
and cable lengths supported
Using more than 6 DBPs on the same 802.3at switch port may result in unreliable beltpack
operation.
To
daisy chain belt backs together
, do the following:
1.
Connect one end of a CAT-5e cable from the
PoE Out connector
on one DBP belt pack
.
2.
Connect the other end of the CAT-5e cable to the
PoE In connector
on a second DBP
belt pack
.
3.
Connect one end of a second CAT-5e cable to the
PoE Out connector on the second DBP
belt pack
.
4.
Connect the other end of the second CAT-5e cable to the
PoE In connector on a third
DBP belt pack
.
5.
Repeat these
steps
to add additional belt packs to the daisy chain.
J2
J3
Figure 4.1:
Daisy Chain Example
Summary of Contents for DBP 4F