ROXELL - 008 - 2111
VITOO IN LINE -- INSTRUCTIONS FOR THE USER
I--12
TROUBLE SHOOTING GUIDE
Switch off the current first. Use protection
DANGER
ACTIONS IN GREY BACKGROUND MUST BE DONE BY A TECHNICALLY TRAINED PERSON.
PROBLEM
CAUSE
CORRECTIVE ACTION
1.None of the feeder
lines run.
No current.
Replace defective fuses or reset circuit breakers.
Check current supply to the house.
Defective clock.
Replace defective clock.
Time clock not properly set.
Readjust tabs.
2.One/more lines do
not run.
Pans are empty
Wires from motor damaged.
Measure current in motor wires. Replace wires if
defective.
Thermal protection of motor switched
off.
See points 3. & 4. Reset motor overload button.
Defective sensor in the control unit, or
sensor not properly adjusted.
Check the good operation of the sensor.
Replace if necessary.
Defective
sensor/minimum
switch
control unit or 100kg hopper.
Check control unit sensor or switch. Replace if
necessary.
3.Motor is often
overloaded.
Oil on auger overloads the motor.
Clean the auger by running repeatedly 25kgs of feed
through the line.
Not enough current supply to the motors. Check current supply at motor location. Start the motor.
Measure start current on motors. Wiring must be thick
enough to guarantee good operation of the system.
Object blocks the auger. Motor runs,
then stalls. Feed sticks to the tubes.
Check if there are no objects in the boot, the control unit
and the drop holes of the feeder pans. Remove any
objects.
4.Auger stalls.
Anchor bearing worn out or broken.
Replace bearing. Gently slide auger back into the tubes.
Don’t let it jump back : your finger or the bearing could
be damaged.
Auger not enough stretched.
Shorten the auger.
Object blocks the auger.
Remove the object.
5.Tubes / boot wear rap-
idly, much noise
when system runs.
Auger kinked or bent at the wear point.
Auger end overlaps the anchor end.
Make sure not to kink the auger when using gripping pli-
ers. Auger must not overlap the anchor end.
6.Not enough feed
supplied to fill up
the lines.
Flex--Auger drop holes are too small or
point upwards.
Make holes wider/turn tubes with holes downwards.
Flow regulator in boot of feed supply
system blocks passage of the feed.
Adjust flow regulator to get a higher capacity.
Flex--Auger capacity is too low.
Check the capacity of the Flex--Auger according the spe-
cifications.
Check the installation of the Flex--Auger.
Not enough time set on the time clock.
Extend operation time per meal.
7.Feed drops directly
on the adjuster ring
of the grill.
Pan not installed over the hole.
Remove the top support. Install the pan ass’y over
the hole and the lips.
8.Irregular distribution
of the feed along
the feeder line.
Bad indexing of tubes or no indexing at
all.
Check indexing.
Switch over to other feed disturbs the in-
dexing of the feeder tube. (Too much or
too little feed in front or at the back.)
1.Too much in front : turn the holes a bit higher.
2.Too little feed in front : turn the holes somewhat lower.
Foreign object in auger.
Remove foreign object.
Feeder tubes turned in relation to each
other.
Check according to the marks when installed. Adjust if
required and tighten clamps securely.
Summary of Contents for Vitoo In Line
Page 6: ...VITOO IN LINE TABLE OF CONTENTS ROXELL 008 3510 ...
Page 7: ...I 0 PART I INSTRUCTIONS FOR THE USER ...
Page 8: ...ROXELL 008 2111 VITOO IN LINE INSTRUCTIONS FOR THE USER I 1 ...
Page 24: ......
Page 26: ...ROXELL 008 3510 VITOO IN LINE COMPONENTS II 2 GENERAL LAY OUT ...
Page 44: ...ROXELL 008 0512 VITOO IN LINE COMPONENTS II 20 BAG HOPPER PARTS ...
Page 53: ...PART III INSTALLATION INSTRUCTIONS ...
Page 54: ...ROXELL 008 4403 VITOO IN LINE INSTALLATION INSTRUCTIONS NOTES ...
Page 56: ......
Page 58: ...ROXELL 008 2111 VITOO IN LINE INSTALLATION INSTRUCTIONS III 4 GENERAL LAY OUT ...