2–4 • Physical Installation
SRG-4400 User Manual (Iss. 06)
Operating Environment Requirements
Verify that the location of your installation has the proper operating environment. The SRG-4400
operates correctly in ambient temperatures from 0 °C to +40 °C and relative humidity from 20%
to 80%.
For More Information on...
• environmental operating specifications, refer to the appendix “
The SRG-4400 requires 50mm (2”) of side clearance for counter top use. Also, ensure sufficient
rear clearance, e.g. 75mm (3”), so that cables are not compromised.
The SRG-4400 does not currently have an internal fan to assist with ventilation or cooling.
Therefore, when you install the unit in an equipment bay, it is imperative that you ensure there is
sufficient space all around the unit to allow the airflow to vent away any excess heat generated by
the unit.
Caution
— The SRG-4400 could be damaged if it is powered on at temperatures or
humidities outside the specified ranges.