Reference Manual
00809-0100-4025, Rev BA
September 2005
C-5
Rosemount 5600 Series
F
OUNDATION
Fiel
dbus
Table C-6. Presentation
Table C-7. Tank Type
Table C-8. Tank Bottom Type
Table C-9. Dielectrical Constant
Bit Number
Value of
Env_Presentation
Description
0
0
-
1
0x00000001
Reserved
2
0x00000002
Reserved
3
0x00000004
Reserved
4
0x00000008
Bottom echo visible
5
0x00000010
Tank contains double bounce
6
0x00000020
Slow Search
7
0x00000040
Double Surfaces
8
0x00000080
Select lower surface
9
0x00000100
-
10
0x00000200
Show negative levels as zero
11
0x00000400
Reserved
12
0x00000800
Reserved
13
0x00001000
Reserved
14
0x00002000
Reserved
15
0x00004000
Invalid level is NOT set if tank is empty
16
0x00008000
If set and if bit 12 not set, Invalid level is NOT set if
tank is full
17
0x00010000
-
18
0x00020000
Reserved
19
0x00040000
Reserved
Value
GEOM_TANK_TYPE
0
Unknown
1
Vertical Cylinder
3
Horizontal Cylinder
4
Spherical
5
Cubical
Value
GEOM_TANK_BOTTOM_TYPE
0
Unknown
1
Flat
2
Dome
3
Cone
4
Flat Inclined
Value
ENV_DIELECTR_CONST
0
Unknown
1
Range (1-2, 5)
2
Range (2, 4-5)
3
Range (4-10)
4
Range (>10)
Summary of Contents for 5600 Series
Page 2: ......
Page 4: ......
Page 18: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series 1 10 ...
Page 64: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series 2 46 ...
Page 80: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series 3 16 ...
Page 99: ...Reference Manual 00809 0100 4024 Rev BA September 2005 4 19 Rosemount 5600 Series ...
Page 100: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series 4 20 ...
Page 174: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series A 20 ...
Page 208: ...Reference Manual 00809 0100 4024 Rev BA March 2004 Rosemount 5600 Series Index 4 ...
Page 209: ......