Reference Manual
00809-0100-4024, Rev BA
September 2005
Rosemount 5600 Series
B-14
1
2
3
4
5
6
INTR. SAFE / Ex ib/ia
SECONDARY OUTPUT (OPTION)
I.S. PRIMARY OUTPUT (OPTION)
–
+
X2
HAZARDOUS AREA
Three se
parate I.S. circuits
TRANSMITTER HEAD TH 43..
NON-HAZARDOUS AREA
CABLE GLANDS OR CONDUIT FITTINGS ½" -14
N
P
T
Note 3.
–
+
E
x d
e [
ib
/ia]
IIC
T6
GAS GROUP
IIB & IIC
GAS G
R
OUP
IIB & IIC
EART
H
CONNECTI
O
N
Area: 4
mm².
DISPLAY PANEL (OPTION)
NON-HAZARDOUS AREA INSIDE
Ui < 30 V, Ii < 200 mA Pi < 1,3 W C
i = 0
μ
F, Li = 0 mH
ALT. D: PASSIVE CURRENT LOOP
ALT. B: A
C
T
IV
E
C
URRENT
LOOP
Uo = 23,1 V, Io = 125
,7
m
A
Po = 0,726 W Co <0,14
μ
F
, L
o
<2,2
mH
Ui < 30 V, Ii < 200 mA Pi < 1,3 W C
i = 0
μ
F, Li = 0 mH
A
LT. 4B:
FOUNDATION
FIELDBUS
ALT. 1D: PASSIVE CURRENT LOOP
X5
X6
X7
Uo = 23,1 V, Io = 125,7
mA
Po = 0,726 W Co <0,14
μ
F
, L
o
<2,2
mH
(Ex ib IIC T4)
X4
–
POWER SUPPLY
4
+
X1
L /L1/+
2
Nominal Input
:
24-240 V DC/AC (
0-60Hz)
max. 10 W.
In
ternal fuse link T 2.5A L 250V
Installation Category III
.
A circuit b
reaker should be
installed clos
e
to
the TR Pro
transmitte
r.
Min. cable
cross-section: 0.5 mm²
1
N/L2/–
3
NON IS PRIMARY OUTPUT
X3
NON IS / Ex e
PE
7
Vcc
DB
Gnd
DA
A
LT. 1B:
A
C
T
IV
E
C
U
R
RENT
LOOP
Ui < 30 V, Ii < 300 mA Pi < 1,3 W C
i = 0
μ
F, Li = 0 mH
GAS G
R
OUP
IIB & IIC
DISPLAY OUTPUT
Uo = 7,84 V, Io = 385,6
mA
Po = 0,678 W Co < 8,8
μ
F
, L
o
<
0,17
mH
Voltage Comp
liance: 7-30 V
M
ax . Load
: 300 Ohm
Max . Load:
300
Ohm
Voltage Comp
liance: 7-30 V
NOTE 5. Cable inductance and capacitance must be included
in the total allowance for each IS circuit.
NOTE 3. Use "Ex e" type of glands with integral cable shield connection.
Shielded cables are required for specified EMC performance.
NOTE 2. Non-IS primary output alternative options.
1A: Active Current Loop. Max. load: 300 Ohm.
1C: Passive Current Loop. Voltage compliance: 7-30 V.
2A: TRL2 Bus (TM40).
3A: Profibus DP (AA40).
4A: Foundation Fieldbus (FF43).
NOTE 1. Installations in Canada shall be in accordance with the applicable
requirements of the Canadian Electrical Code (CEC), Part I.
NOTE 4. Use certified multiple conductor cable with individually
shielded, twisted pairs, rated at least 300 V and 90°C.
Note 2.
IS CABLE - Notes 4, 5.
Note 1
1
0216
SME-3022
ISSUE
ISSUE
ISSUE
CHANGE ORDER No
WEEK
WEEK
WEEK
CHANGE ORDER No
CHANGE ORDER No
GU-MK
0216
TR PRO
GU-HN
2
Y
E
S
9150 074-939
91
5
0 074-939
0216
INSTALLATION DRAWING EL.
For installation of CSA (CENELEC)
1
1 / 1
approved apparatus (Ex e / Ex i)
ISSUED BY
APPROVED BY
WEEK
WEEK
PRODUCT CODE
DOC. TYPE
FILE
TITLE
DWG NO.
ISSUE
SHEET
S
C
ALE
1:1
1 ST ANG
L
E
FINISH, UNLESS
OTHERWISE S
TATED:
ALL DIMENSIONS ARE IN MILLIMETRES.
The copyright/ownership of this document is and will remain ours.
The document must not be used without our authorization or brought
to the knowledge of a third party. Contravention will be prosecuted.
Saab Marine Electronics AB
, Sweden
RD
BK
BU
GR
NOTE 6. Substitution of components may impair intrinsic safety.
The Entity concept allows interconnection of intrinsically safe apparatus,
not specifically examined in combination as a system, when the Approved
values of Uo, Io and Po for the assosiated apparatus are less than or
equal to Ui, Ii and Pi for the intrincically safe apparatus, and the Approved
values of Co and Lo for the assosiated apparatus are greater than Ci +
cable capacitance and Li + cable inductance.
56005600_1
1_AA.EP
S
Summary of Contents for 5600 Series
Page 2: ......
Page 4: ......
Page 18: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series 1 10 ...
Page 64: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series 2 46 ...
Page 80: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series 3 16 ...
Page 99: ...Reference Manual 00809 0100 4024 Rev BA September 2005 4 19 Rosemount 5600 Series ...
Page 100: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series 4 20 ...
Page 174: ...Reference Manual 00809 0100 4024 Rev BA September 2005 Rosemount 5600 Series A 20 ...
Page 208: ...Reference Manual 00809 0100 4024 Rev BA March 2004 Rosemount 5600 Series Index 4 ...
Page 209: ......