Galaxy Raid GHDX4 SAS<>-SAS/SATA 12Bay
Installation / Hardware Reference Manual
2-22
Front Bezel Rotary Lock
Step 6.
Once the drive bays are populated and the system is
powered on, the RAID controller will automatically
spin up the hard drives and recognize their presence.
2.10 Installing CBM (Optional)
The CBM (Cache Backup Module) is an optional item for the
single-controller subsystem. If purchased, install the CBM on the
arrival of your system before installing the RAID controller into the
subsystem.
To install a CBM module (Skip steps 1-4 if installing CBM in a new
system):
Step 1.
1-1. If a system is powered on, stop host I/Os.
1-2. Use the “Shutdown Controller” command to flush
cached data.
1-3. Power down the system.
Step 2.
Remove RAID controller from the chassis by loosening
screws under the ejection levers.
Step 3.
Press down on the ejection levers. The controller will
be eased out from chassis.