![Rohde & Schwarz ZVT Series Getting Started Download Page 86](http://html.mh-extra.com/html/rohde-and-schwarz/zvt-series/zvt-series_getting-started_1477905086.webp)
System Overview
R&S
®
ZVT
86
Getting Started 1300.0045.62 ─ 10
complete list of options, accessories, and extras refer to the product brochure of your
analyzer.
Table 3-3: R&S ZVT options
Option
Option Name
Functionality
RS& ZVAB-K2
Time Domain
Transformation of the trace to time domain in order to analyze
responses, transformation back to the frequency domain.
R&S ZVA-K4
Arbitrary gen. and rec. frequen-
cies, includes scalar Mixer and
Harmonics measurements
Measurements at arbitrary (not necessarily equal) generator and
receiver frequencies; scalar measurements on external RF mix-
ers, harmonic distortion measurements, intermodulation distor-
tion measurements.
R&S ZVA-K5
Mixer Phase Measurement (Vec-
tor Mixer Measurement)
Measurement of the parameters of an external mixer including
phase, e.g. the complex conversion loss or reflection coeffi-
cients.
R&S ZVA-K6
True Differential Mode
Generation of true differential and common mode stimuli at arbi-
trary reference planes in the test setup and measurement of the
mixed-mode S-parameters, wave quantities and ratios. Alterna-
tively: Defined coherence mode, provides several source signals
with defined phase and amplitude relation.
R&S ZVA-K7
Measurements on Pulsed Signals
Pulsed measurements in analogy to a time sweep (i.e. at con-
stant receiver frequency), but with a much higher sampling rate
of 12.5/ns.
R&S ZVA-K8
Converter Control
Measurements at frequencies beyond the analyzer's operating
range.
R&S ZVA-K9
Mixer Delay w/o LO Access
Measurement of the absolute or relative group delay of a mixer.
R&S ZVA-K10
Long Distance Mixer Delay
Mixer delay measurement with two different network analyzers,
one providing the source ports, the other the receive port.
R&S ZVA-K17
5 MHz Receiver Bandwidth
Provides up to 5 MHz IF bandwidth, thus providing shorter mea-
surement times for frequency, time, or CW sweeps; enhanced
performance for point-in-pulse measurements.
R&S ZVA-K27
Internal Pulse Generators
Provides two pulsed control signals to control pulsed measure-
ments.
R&S ZVAB-K30
Noise Figure Measurement
Provides the noise figure of a DUT which operates in its linear
range.
R&S ZVA-K31
Freq. Conv. Noise Figure
Provides the noise figure of a frequency-converting DUT which
operates in its linear range.
R&S ZVAB-B4
Oven Quartz (OCXO)
The R&S ZVT can optionally be equipped with a 10 MHz oven-
controlled crystal oscillator (OCXO) to enhance the frequency
accuracy of the internal generators.
R&S ZVT20-B11
Internal Combiner
(R&S ZVT20 only)
The internal combiner option for the R&S ZVT20 combines the
signals of two internal sources inside the analyzer to deliver a
two-tone signal at port 1.
R&S ZVT<frequency>-B16
Direct Generator/Receiver Access Give direct access to various RF input and output signals, e.g. to
insert external components into the signal path or develop cus-
tom measurements.
Optional R&S ZVT Extensions