Search
R&S
®
RTM20xx
143
User Manual 1317.4726.02 ─ 01
Hysteresis
Sets a hysteresis range to the search level of the selected signal in order to avoid unwan-
ted search results caused by noise oscillation around the level. For a rising edge, the
hysteresis is below the search level. Otherwise, for a falling edge the hysteresis is above
the level.
Remote command:
10.3.7.2
Data2Clock Setup
Access: SEARCH MENU > "Search type = Data2Clock" > "Setup"
Polarity
Sets the edge of the clock signal to define the time reference point for the setup and hold
time.
"Rising"
Only positive clock edges are considered.
"Falling"
Only negative clock edges are considered.
"Either"
The clock edges next to the data edge are considered regardless of the
clock slope.
Remote command:
Setup Time
Sets the minimum time
before
the clock edge while the data signal must stay steady
above or below the data level. The setup time can be negative. In this case, the setup
interval starts after the clock edge, and the hold time must be positive and longer than
the absolute value of the setup time.
Remote command:
Reference for Search Menu