Measurements
R&S
®
RTM20xx
88
User Manual 1317.4726.02 ─ 01
Mean Value
Determines the mean value of the complete displayed waveform. The measurement
value is displayed as "Mean" in the result table.
RMS Value
Measures the RMS (Root Mean Square) value of the voltage of the complete displayed
waveform. The measurement value is displayed as "RMS" in the result table.
Mean Cycle
Measures the mean value of the left-most signal period. The measurement value is dis-
played as "MnCy" in the result table.
RMS Cycle
Measures the RMS (Root Mean Square) value of the voltage of the left-most signal
period. The measurement value is displayed as "RMSCy" in the result table.
Peak Peak
Measures the peak-to-peak value within the displayed section of the waveform. The
measurement value is displayed as "Vpp" in the result table.
Peak +
Measures the maximum value within the displayed section of the waveform. The mea-
sured value is displayed as "Vp+" in the result table.
Peak -
Measures the minimum value within the displayed section of the waveform. The mea-
sured value is displayed as "Vp-" in the result table.
Frequency
Measures the frequency of the signal. The result is based on the length of the left-most
signal period within the displayed section of the waveform. The measurement value is
displayed as "f" in the result table.
Automatic Measurements