Windows
Application CTSgo
CTS-K6
1079.2001.01
50
E-3
The standard BS output power is used for the following measurements:
•
Frequency
error
•
Phase error (RMS and peak value are determined numerically)
•
Phase error (phase error curve within burst)
•
Bit timing
•
Average burst power
•
Graphics display of power ramp
•
Echo test
The BER base-station power is used for the remaining measurements:
•
BER class Ib
•
BER class II
•
BER EFR (Erased Frames)
•
RXQual
•
RXLev
The measurements are repeated at all power levels (PCLs) selected in the boxes.
As an option, the test set can be assigned a short name, which will also be displayed in the menu.
The graphics display of power ramp and phase error is shown in the appendix when the measurement
report is generated. E-GSM channels are part of network GSM900. The attenuation values shown in
this dialog are channel depending. These values are only shown for your information.
Note:
This command can only be selected if test set 1 is activated for the test.
Fig.: Configure Test Set dialog window