Logic Status Word for PowerFlex 750-Series Drives
Logic Bits
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Command
Description
x
Run Ready
0 = Not ready to run
1 = Ready to run
x
Active
0 = Not active
1 = Active
x
Command Direction
0 = Reverse
1 = Forward
x
Actual Direction
0 = Reverse
1 = Forward
x
Accelerating
0 = Not accelerating
1 = Accelerating
x
Decelerating
0 = Not decelerating
1 = Decelerating
x
Alarm
0 = No alarm (Par. 959 and 960)
1 = Alarm
x
Fault
0 = No fault (Par. 952 and 953)
1 = Fault
x
At Setpt Spd
0 = Not at setpoint speed
1 = At setpoint speed
x
Manual
0 = Manual mode not active
1 = Manual mode active
x
Spd Ref ID 0
00000 = Reserved
00001 = Auto Ref A (Par. 545)
00010 = Auto Ref B (Par. 550)
00011 = Auto Preset Speed 3 (Par. 573)
00100 = Auto Preset Speed 4 (Par. 574)
00101 = Auto Preset Speed 5 (Par. 575)
00110 = Auto Preset Speed 6 (Par. 576)
00111 = Auto Preset Speed 7 (Par. 577)
01000 = Reserved
01001 = Reserved
01010 = Reserved
01011 = Reserved
01100 = Reserved
01101 = Reserved
01110 = Reserved
01111 = Reserved
10000 = Man Port 0
10001 = Man Port 1
10010 = Man Port 2
10011 = Man Port 3
10100 = Man Port 4
10101 = Man Port 5
10110 = Man Port 6
10111 = Reserved
11000 = Reserved
11001 = Reserved
11010 = Reserved
11011 = Reserved
11100 = Reserved
11101 = Man Port 13 (embedded EtherNet/
IP)
11110 = Man Port 14 (DriveLogix™)
11111 = Alternate Man Ref Sel
x
Spd Ref ID 1
x
Spd Ref ID 2
x
Spd Ref ID 3
x
Spd Ref ID 4
x
Reserved
x
Running
0 = Not running
1 = Running
x
Jogging
0 = Not jogging (Par. 556 and 557)
1 = Jogging
x
Stopping
0 = Not stopping
1 = Stopping
x
DC Brake
0 = Not DC brake
1 = DC Brake
x
DB Active
0 = Not dynamic brake active
1 = Dynamic brake active
x
Speed Mode
0 = Not Speed Mode (Par. 309)
1 = Speed Mode
x
Position Mode
0 = Not Position Mode (Par. 309)
1 = Position Mode
x
Torque Mode
0 = Not Torque Mode (Par. 309)
1 = Torque Mode
x
At Zero Speed
0 = Not at zero speed
1 =At zero speed
x
At Home
0 = Not at home
1 = At home
x
At Limit
0 = Not at limit
1 = At limit
x
Current Limit
0 = Not at current limit
1 = At current limit
x
Bus Freq Reg
0 = Not Bus Freq Reg
1 = Bus Freq Reg
Summary of Contents for Allen-Bradley PowerFlex 700AFE
Page 8: ...8 Rockwell Automation Publication 20Y UM001F EN P April 2017 Table of Contents Notes ...
Page 164: ...164 Rockwell Automation Publication 20Y UM001F EN P April 2017 Appendix B HIM Overview Notes ...
Page 184: ...184 Rockwell Automation Publication 20Y UM001F EN P April 2017 Index Notes ...
Page 185: ......