68
Rockwell Automation Publication 20P-TG003B-EN-P - September 2021
Chapter 3
Access Procedures
2.
Connect the leads of the multimeter to pins 13 and 14 of connector XR on
the pulse transformer board (polarity is not important) and, using the TA
potentiometer in the center of the pulse transformer circuit board, set the
total resistance (RTA) to the appropriate value as indicated in
in the
.
1 . . . . . . . . . . . . . .13 . . . . . . . . . . . . . . . . . . . . 33
2 . . . . . . . . . . . . . 14 . . . . . . . . . . . . . . . . . . . 34
XR
The XR connector is located on the
upper right corner of the pulse
transformer circuit board.
The TA potentiometer is located on the lower
right corner of the pulse transformer circuit
board next to the control power terminal block.