
44
Rockwell Automation Publication 20P-TG003B-EN-P - September 2021
Chapter 3
Access Procedures
5.
Loosen, but do not remove, the screws that secure the top cover to the
drive, then slide the cover up and off the drive chassis.
6.
Disconnect the HIM communication cable from the connector on the
upper right corner of the control board and set the cover aside.
IMPORTANT
The HIM assembly is connected via a cable to the control board and
therefore will not pull free from the drive until disconnected. See step 5
below for instructions.
STS
PORT
MOD
NET A
NET B
FU1
FV1
U
V
C
D
W
Tightening torque:
0.8 N
•
m (7 lb
•
in)
Tightening torque:
0.8 N
•
m (7 lb
•
in)
Pull tabs out to
disconnect cable.