9.
Carefully disconnect the cables from connectors XFCD, XA and XR on
the control board.
10.
Remove the plug-in I/O and control terminal blocks with the wiring kept
in place.
11.
Remove the five screws that secure the control board to the control EMI
shield and remove the board.
Disconnect
cables
Disconnect I/O
and control
wiring
=
Remove
screws
Tightening torque for
re-assembly is
1.0 N
•
m (8.9 lb
•
in)