14
Rockwell Automation Publication 2711T-QS002C-EN-P - March 2019
Second Generation MobileView Tethered Operator Terminal
The following instructions also apply to the back cover plate accessory.
To mount the back plate of an IP65 junction box, perform the following steps.
1.
Determine where to mount the junction box.
Use the dimensions in
to decide where to locate the junction box in a safe area
that is easily accessible for a terminal operator.
Figure 4 - IP65 Junction Box Dimensions (for 2711T-JBIP65DC1 and 2711T-JBIP65DM1)
2.
Use the back plate or the supplied cutout template to mark where to drill the four
mounting holes for the junction box.
3.
With a drill and drill bit, drill the four holes.
4.
Attach the back plate to the mounting surface.
IMPORTANT
Take precautions so metal cuttings do not enter components already installed in
the control cabinet or in the junction box.
TIP
Use four M4 bolts with a maximum bolt head diameter of 9 mm, and with
self-locking M4 nuts.
However, the fasteners depend on the material of the mounting surface, such as
the wall of a control cabinet or a machine.
132.5 mm
(5.22 in.)
140 mm (5.5 in.)
70 mm
(2.76 in.)
210 mm (8.27 in.)
172 mm (6.77 in.)
160 mm
(6.3 in.)