46
Rockwell Automation Publication 2711T-QS002C-EN-P - March 2019
Second Generation MobileView Tethered Operator Terminal
IP65 Junction Box Specifications
General
Electrical
Attribute
Cat. No. 2711T-
JBIP65DC1
JBIP65DM1
USB drive slot
Yes (2.0)
Communication
10/100 Ethernet
Dimensions
See
Weight, approx
500 g (1.1 lb)
Cat. No. 2711T-
Attribute
JBIP65DC1
JBIP65DM1
Rated supply voltage
24V DC
Supply voltage tolerance range
19.2…30V DC (EN 61131-2)
Input current
(1)
(1)
Without a MobileView terminal connected to the junction box.
500 mA at 24V DC
Peak inrush current
5.6 A (max)
Connector cycle duration
(2)
(2)
Applies to black, 22-pin cable connector. Test the connector monthly to verify that it locks properly. Remove the IP65 junction
box from operation after the connection cycles have been exceeded.
5000 (typical)
E-stop functions
• Voltage, min
• Current, min (Ie)
• Current carrying capacity, min
• Usage category
• Reaction time, max
(3)
• Isolation
• Bounce time
• Proof-test interval
(4)
• Switching cycles relay
• PFH
d
(3)
Reaction time is time before the E-stop is triggered.
(4)
Decommission the safety function once the E-stop has been activated 250,000 times or after 20 years, whichever comes first.
• 5V DC per contact
• 10 mA per contact
• 1000 mA per contact
• DC-13 (IEC 60947-5-1)
• 19 ms
• 500V AC to rest
• <10 ms
• 20 years
• 10 x 10
5
• 9.79 x 10
-10